E44 Door interlock sensing circuit triac faulty PCB faulty. E45 Door interlock sensing circuit triac faulty (wrong input signal to microprocessor) PCB faulty.
E52 No signal from motor tachometric generator E57 Inverter is drawing too much current ( >15A) E58 Inverter is drawing too much current ( >4,5A) E59 No signal from tachometric generator for three seconds E5A Overheating for heat dissipator for Inverter E5H Input voltage is lower than 175V E5C Input voltage is too high E5d Data transfer error between Inverter and main board E5E Wrong communication between main board and Inverter E5F Inverter board does not start the motor E61 Insufficient heating during washing E62 Overheating during washing (temperature higher than 88°C for a time higher than 5 min.) E66 Heating element power relay faulty (incongruence between sensing and relay) PCB faulty.
E68 Current dispersion to earth (value of mains voltage different from main value) E69 Heating element interrupted E71 Washing NTC sensor faulty (short- circuited or open) board faulty. faulty. E74 Washing NTC sensor badly positioned faulty. QUICK GUIDE AND APPLIANCES LIST Alarm Possible fault ENV06 EWM11xx EWM21xx EWM25xx/35xx E72 Drying condenser NTC sensor faulty (voltage value out of limits, sensor short- circuited or open) E73 Drying duct NTC sensor faulty (voltage value out of limits, sensor short-circuited or open) Alarm Possible fault Action/machine status Reset Alarm E44 Door interlock sensing circuit triac faulty PCB faulty. (Safety drain cycle) Cycle blocked.
ON/OFF RESET E45 Door interlock sensing circuit triac faulty (wrong input signal to microprocessor) PCB faulty. (Safety drain cycle) Cycle blocked. ON/OFF RESET E52 No signal from motor tachometric generator Motor faulty; wiring faulty; PCB faulty. Cycle blocked, door locked (after 5 attempts). RESET E57 Inverter is drawing too much current (>15A) Motor-Inverter wiring faulty; Inverter board faulty, Motor faulty. Cycle blocked, door locked (after 5 attempts). RESET E58 Inverter is drawing too much current (>4,5A) Motor abnormal operation (overloaded); Motor-Inverter wiring faulty; Motor faulty; Inverter board faulty. Cycle blocked, door locked (after 5 attempts).
RESET E59 No signal from tachometric generator for three seconds Motor-Inverter wiring faulty; Inverter board faulty, Motor faulty. Cycle blocked, door locked (after 5 attempts). RESET E5A Overheating for heat dissipator for Inverter Overheating caused by continuous operation or ambient conditions (let appliance cool down); Inverter board faulty. NTC open (on the Inverter board). Cycle blocked, door locked (after 5 attempts). RESET E5H Input voltage is lower than 175V Wiring faulty; Inverter board faulty. Cycle blocked, door locked (after 5 attempts). RESET E5C Input voltage is too high Input voltage is too high (measure the masters voltage); Inverter board faulty.
Cycle blocked, door locked (after 5 attempts). RESET E5d Data transfer error between Inverter and main board Line interference; Wiring faulty; Main board or Inverter faulty. ---------------- RESET E5E Wrong communication between main board and Inverter Main board-Inverter wiring faulty; Inverter board faulty; Main board faulty. Cycle blocked (after 5 attempts). ON/OFF E5F Inverter board does not start the motor Wiring faulty; Inverter board faulty; Main board faulty. Cycle blocked, door locked (after 5 attempts). RESET E61 Insufficient heating during washing NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. The heating phase is skipped.
START/RESET E62 Overheating during washing (temperature higher than 88°C for a time higher than 5 min.) NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET E66 Heating element power relay faulty (incongruence between sensing and relay) PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET E68 Current dispersion to earth (value of mains voltage different from main value) Current dispersion between between heating element and earth. Cycle blocked with door open. RESET E69 Heating element interrupted Wiring faulty; Heating element for washing interrupted (thermofuse open).
---------------- START/RESET E71 Washing NTC sensor faulty (short- circuited or open) Wiring faulty; Washing NTC sensor faulty; PCB faulty. The heating phase is skipped. START/RESET E72 Drying condenser NTC sensor faulty (voltage value out of limits, sensor short- circuited or open) Wiring faulty; Drying NTC sensor (condenser) badly positioned or faulty; WD board faulty. The drying heating phase is skipped. START/RESET E73 Drying duct NTC sensor faulty (voltage value out of limits, sensor short-circuited or open) Wiring faulty; Drying NTC sensor (duct) badly positioned or faulty; WD board faulty. The drying heating phase is skipped.
START/RESET E74 Washing NTC sensor badly positioned Wiring faulty; Washing NTC sensor badly positioned; NTC sensor faulty; PCB faulty. The heating phase is skipped. START/RESET