Time-Out - WATER FILL ALARM - The water fill time-out is set to 5 minutes . - The time-out count begins at the start of each fill phase, and ends when a "FULL " signal is received from the pressure switch (1-3). - If the "FULL" signal (1-3) is not received within 5 minutes , the Time-out intervenes to generate an ALARM condition. Time-Out - WATER REPLENISHMENT ALARM - The water replenishment time-out subsequent to resetting of the pressure switch to the "EMPTY" state is set to 90 seconds . - This safety system is activated only during washing phases without heating , and starts from the moment at which the volumetric level is reached, ending with the subsequent drain cycle.
- The count begins when the pressure switch resets to "EMPTY" (1-2) and ends when the "FULL" signal is received from the pressure switch (1-3). - If the "FULL" signal (1-3) is not received within 90 seconds , the Time-out intervenes to generate an ALARM condition. - If the pressure switch is reset more than once, the total times utilized for replenishment are summed; the total must not exceed 90 seconds . - During the replenishment phase, only the fill solenoid is switched on; all the other loads are disabled. Time-Out - PRESSURE SWITCH "EMPTY" ALARM - The time for resetting of the pressure switch to "EMPTY" during the washing and heating phase is set to 2 minutes .
- The count starts from the moment the pressure switch resets to "EMPTY" (1-2), and ends when the "FULL" signal is received from the pressure switch (1-3). - If the "FULL" signal (1-3) is not received within the 2 minute period, a time-out intervenes to generate an ALARM condition. - If the pressure switch is reset more than once to "EMPTY" (for a total time not exceeding the limit), this may take place up to 3 times ; if a further reset occurs, an ALARM condition is generated. - All the loads are disabled while the pressure switch is set to "EMPTY" . 16