10.9 Universal motor (EWM 21xx) 11 Tachometric generator 12 Stator 13 Protector 14 Rotor 20 PCB 10.9.1 Power supply to motor The PCB powers the motor via a triac. The direction of rotation is reversed by switching of the contacts on the two relays (K2-K3), which modify the connection between the rotor and the stator. In certain models, a third relay (K4) is used to power the stator (full or half field) according to the spin speed. The speed of rotation of the motor is determined by the signal received from the tachometric generator. During the spin phases, the microprocessor performs the anti-foam and the anti-unbalancing control procedure. 10.10 Three-phase asynchronous motor (EWM25xx) 11.
Tachometric generator 20. PCB 23. Inverter 24. Motor X-Y-X = Motor windings 10.10.1 Power supply to motor Three-phase power is fed by the inverter (4) which sends, through the connectors 5-6-7, the three phases to connectors 1-2-3 on the motor (nodes V-W-U), where the windings (Y-X-Z-) are connected. The phase shift between the phases is 120° and peak amplitude is 310V. The condition of the motor can be determined by measuring the resistance of the windings: Winding y ohm 5,4 ±7% (contacts 2-3) Winding x ohm 5,4 ±7% (contacts 1-2) Winding z ohm 5,4 ±7% (contacts 1-3) Winding T (tachometric) ohm 121 ±7% (contacts 4-5) ѓ The electrical components must be serviced by qualified personnel only.
ѓ Unplug the appliance before accessing internal components. SOI/DT 2007-11 dmm 47/69 599 70 39-88