electrolux EWM21xx EWM25xx — Electrolux EWM21xx EWM25xx Washing Machines & Washer-Dryers Service Manual

SOI/DT 2007-11 dmm E83 PCB faulty (Wrong configuration data). Selector, wiring E92 Wrong control/display board; Wrong PCB (do not correspond to the model). E93 Incorrect configuration data; PCB faulty. E94 Incorrect configuration data; PCB faulty. E98 Incompatibility between main board and Inverter. E9b / E9H Display board. E9C Display board. E9d Display board. E9F PCB. EH1 EH2 EH3 EC3 Wiring faulty; Weight sensor faulty; PCB faulty. Ed1 EF1 Drain tube blocked/kinked/too high; Drain filter dirty/blocked. EF3 Alarm Possible fault Action/machine status Reset E82 PCB faulty (Wrong configuration data). Selector, wiring E91 Wiring faulty; Faulty control/display board PCB faulty. E95 PCB faulty.

E97 Faulty PCB (Wrong configuration data). EHE Wiring faulty; PCB faulty. EHF PCB faulty. EC1 Solenoid valve faulty/blocked; PCB faulty. Ed2 Ed3 Ed4 Wiring faulty: WD board faulty; PCB faulty. EF2 Excessive detergent dosing; drain tube kinked/blocked; Drain filter dirty/blocked. EF4 Tap closed, water pressure too low. Alarm Possible fault Action/machine status Reset E82 PCB faulty (Wrong configuration data). Selector, wiring ---------------- RESET E83 PCB faulty (Wrong configuration data). Selector, wiring Cycle cancelled. START/RESET E91 Wiring faulty; Faulty control/display board PCB faulty. ---------------- RESET E92 Wrong control/display board; Wrong PCB (do not correspond to the model).

Cycle interrupted. OFF/ON START E93 Incorrect configuration data; PCB faulty. Cycle interrupted. OFF/ON E94 Incorrect configuration data; PCB faulty. Cycle interrupted. OFF/ON E95 PCB faulty. Cycle interrupted. RESET E97 Faulty PCB (Wrong configuration data). Cycle interrupted. RESET E98 Incompatibility between main board and Inverter. Cycle interrupted. OFF/ON E9b / E9H Display board. Cycle interrupted. ON/OFF RESET E9C Display board. Cycle interrupted. ON/OFF RESET E9d Display board. Cycle interrupted. ON/OFF RESET E9F PCB. Cycle interrupted. OFF/ON EH1 Power supply problems (incorrect / disturbance); PCB faulty. Wait for frequency nominal conditions.

OFF/ON EH2 Power supply problems (incorrect / disturbance); PCB faulty. Wait for voltage nominal conditions. OFF/ON EH3 Power supply problems (incorrect / disturbance); PCB faulty. Wait for voltage nominal conditions. OFF/ON EHE Wiring faulty; PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET EHF PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET EC1 Solenoid valve faulty/blocked; PCB faulty. Cycle interrupted with door closed. Drain pump functions always (5 min., then it stops for 5 min. etc.) RESET EC3 Wiring faulty; Weight sensor faulty; PCB faulty. ---------------- START/RESET Ed1 Wiring faulty between PCB and WD board; WD board faulty; PCB faulty.

Cycle interrupted. OFF/ON Ed2 Wiring faulty between PCB and WD thermostats; WD board faulty; PCB faulty. Cycle interrupted with door open. RESET Ed3 Wiring faulty between PCB and WD thermostats; WD board faulty; PCB faulty. Cycle interrupted with door open. RESET Ed4 Wiring faulty: WD board faulty; PCB faulty. Cycle interrupted with door open. RESET EF1 Drain tube blocked/kinked/too high; Drain filter dirty/blocked. Warning displayed at the end of cycle (specific LED). START/RESET EF2 Excessive detergent dosing; drain tube kinked/blocked; Drain filter dirty/blocked. Warning displayed after 5 attempts or by the specific LED.

RESET EF3 Water leaks onto base frame; water control system defective. Machine drains and cycle stops ON/OFF RESET EF4 Tap closed, water pressure too low. --------------------------- RESET