SOI/DT 2007-11 dmm E5E defective main board. E61 E69 Washing heating element interrupted (thermofuse open) E71 Faulty NTC sensor; Wiring faulty; PCB faulty. E72 E73 E74 Alarm Possible fault Action/machine status Reset E51 PCB faulty; current leakage from motor or from wiring. E52 Motor faulty; wiring faulty; PCB faulty. E53 PCB faulty. E54 PCB faulty; current leakage from motor or from wiring. E57 E58 operation (motor overloaded); E59 Motor defective; Wiring defective on inverter for motor; Inverter board defective. E5H Wiring defective, Inverter board defective. E5C voltage). E5d E5F E62 E66 PCB faulty. E68 Earth-leakage between heater and earth. E5A cool down).
Alarm Possible fault Action/machine status Reset E51 PCB faulty; current leakage from motor or from wiring. Cycle blocked, door locked (after 5 attempts). RESET E52 Motor faulty; wiring faulty; PCB faulty. Cycle blocked, door locked (after 5 attempts). RESET E53 PCB faulty. Cycle blocked, door locked. RESET E54 PCB faulty; current leakage from motor or from wiring. Cycle blocked, door locked (after 5 attempts). RESET E57 Wiring defective on inverter for motor, inverter board defective. Cycle stops with door locked (after 5 attempts). RESET E58 Wiring defective on inverter for motor, inverter board defective, abnormal motor operation (motor overloaded); Motor defective.
Cycle stops with door locked (after 5 attempts). RESET E59 Motor defective; Wiring defective on inverter for motor; Inverter board defective. Cycle stops with door locked (after 5 attempts). RESET E5A Inverter board defective. NTC open (on the inverter board). Overheating caused by continuous operation or ambient conditions (let appliance cool down). Cycle stops with door locked (after 5 attempts). RESET E5H Wiring defective, Inverter board defective. Cycle stops with door locked (after 5 attempts). RESET E5C Inverter board defective, the masters voltage is too high (measure the masters voltage). Cycle stops with door locked (after 5 attempts).
RESET E5d Line interference, Wiring defective, defective main board or inverter board. Cycle stops with door locked (after 5 attempts). RESET E5E Defective wiring between main board and inverter board, Defective inverter board, defective main board. Cycle stops ON/OFF E5F Defective inverter board, Defective wiring, defective main board. Cycle stops with door locked (after 5 attempts). RESET E61 NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. The heating phase is skipped. START/RESET E62 NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET E66 PCB faulty.
Safety drain cycle – Cycle stopped with door open. RESET E68 Earth-leakage between heater and earth. Cycle blocked with door open. RESET E69 Washing heating element interrupted (thermofuse open) ---------------- START/RESET E71 Faulty NTC sensor; Wiring faulty; PCB faulty. Heating is skipped. START/RESET E72 Wiring faulty; Drying NTC sensor (condenser) faulty; PCB faulty. Drying heating is skipped START/RESET E73 Wiring faulty; Drying NTC sensor (duct) faulty; PCB faulty. Drying heating is skipped START/RESET E74 NTC sensor improperly positioned; Faulty NTC sensor; Wiring faulty; PCB faulty. Heating is skipped. START/RESET