SOI/DT 2007-11 dmm 599 70 39-88 E11 faulty; Wiring faulty; PCB faulty. E12 faulty; Wiring faulty; PCB faulty. E13 Drain tube improperly positioned; Water pressure too low; Pressure switch faulty. E21 between heating element and ground. E22 between heating element and ground. E32 Wiring; main board. E38 E41 Door lock unit faulty; Wiring faulty; PCB faulty. E42 Door lock unit faulty; Wiring faulty; PCB faulty. Current dispersion from heating element to ground. E43 Door lock unit faulty; Wiring faulty; PCB faulty. E44 PCB faulty. E45 PCB faulty. 11.2 Table of alarm codes Alarm E23 Drain pump faulty; Wiring faulty; PCB faulty. E24 PCB faulty. E31 Pressure switch; Wiring; Main PCB.
E3A PCB faulty. E35 Pressure switch faulty; Wiring faulty; PCB faulty. Alarm Possible fault Action/machine status Reset E11 Tap closed or water pressure too low; Drain tube improperly positioned; Water fill solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty. Cycle is paused with door locked. START/RESET E12 Tap closed or water pressure too low; Drain tube improperly positioned; Water fill solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty. Cycle is paused with door locked.
START/RESET E13 Drain tube improperly positioned; Water pressure too low; Water fill solenoid valve is faulty; Water circuit on pressure switch is leaking/clogged; Pressure switch faulty. Cycle is paused with door locked. START/RESET E21 Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty; Electrical current leak between heating element and ground. Cycle is paused (after 2 attempts).
START/RESET E22 Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty; Electrical current leak between heating element and ground. Cycle is paused START/RESET E23 Drain pump faulty; Wiring faulty; PCB faulty. Safety drain cycle - Cycle stops with door unlocked. RESET E24 PCB faulty. Safety drain cycle - Cycle stops with door unlocked. RESET E31 Pressure switch; Wiring; Main PCB. Cycle stops with door locked. RESET E32 Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Water circuit on pressure switch; pressure switch; Wiring; main board. Cycle is paused.
START/RESET E35 Water fill solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty. Cycle stops. Safety drain cycle. Drain pump continues to operate (5 min. on, then 5 min. off, etc.). RESET E38 Water circuit on pressure switches; Pressure switches; Motor belt broken. Heating phase is skipped. ON/OFF RESET E3A PCB faulty. Cycle stops with door locked. RESET E41 Door lock unit faulty; Wiring faulty; PCB faulty. Cycle is paused. START/RESET E42 Door lock unit faulty; Wiring faulty; PCB faulty. Current dispersion from heating element to ground. Cycle is paused. START/RESET E43 Door lock unit faulty; Wiring faulty; PCB faulty.
(Safety drain cycle) Cycle stops. ON/OFF RESET E44 PCB faulty. (Safety drain cycle) Cycle stops. ON/OFF RESET E45 PCB faulty. (Safety drain cycle) Cycle stops. ON/OFF RESET