2007-10 SOI/DT-mdm FCPD-dp Quality-fz Alarm Possible fault Page E11 faulty; Wiring faulty; PCB faulty. 18 E13 Drain tube improperly positioned; Water pressure too low; Pressure switch faulty. 20 E21 between heating element and ground. 22 E23 Drain pump faulty; Wiring faulty; PCB faulty. 24 E24 PCB faulty. 25 E31 Pressure switch; Wiring; Main PCB. 25 26 27 E38 28 E3A PCB faulty. 29 E41 Door lock unit faulty; Wiring faulty; PCB faulty. 30 E42 to ground. 32 E43 Door lock unit faulty; Wiring faulty; PCB faulty. 33 E44 PCB faulty. 34 E45 PCB faulty. 34 E51 PCB faulty; current leakage from motor or from wiring. 35 E52 Motor faulty; wiring faulty; PCB faulty. 36 E53 PCB faulty.
40 pump faulty; Water circuit on pressure switch; pressure switch; Wiring; main board. E35 Pressure switch faulty; Wiring faulty; PCB faulty. 5.5 SUMMARY TABLE OF ALARMS E32 Alarm Possible fault Action/machine status Reset Page E11 Tap closed or water pressure too low; Drain tube improperly positioned; Water fill solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty. Cycle is paused with door locked. START/RESET 18 E13 Drain tube improperly positioned; Water pressure too low; Water fill solenoid valve is faulty; Water circuit on pressure switch is leaking/clogged; Pressure switch faulty. Cycle is paused with door locked.
START/RESET 20 E21 Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Pressure switch faulty; Wiring faulty; PCB faulty; Electrical current leak between heating element and ground. Cycle is paused (after 2 attempts). START/RESET 22 E23 Drain pump faulty; Wiring faulty; PCB faulty. Safety drain cycle - Cycle stops with door unlocked. RESET 24 E24 PCB faulty. Safety drain cycle - Cycle stops with door unlocked. RESET 25 E31 Pressure switch; Wiring; Main PCB. Cycle stops with door locked.
RESET 25 E32 Drain tube kinked/clogged/improperly positioned; Drain filter clogged/dirty; Drain pump faulty; Water circuit on pressure switch; pressure switch; Wiring; main board. Cycle is paused. START/RESET 26 E35 Water fill solenoid valve is faulty; Leaks from water circuit on pressure switch; Pressure switch faulty; Wiring faulty; PCB faulty. Cycle stops. Safety drain cycle. Drain pump continues to operate (5 min. on, then 5 min. off, etc.). RESET 27 E38 Water circuit on pressure switches; Pressure switches; Motor belt broken. Heating phase is skipped. RESET 28 E3A PCB faulty. Cycle stops with door locked. RESET 29 E41 Door lock unit faulty; Wiring faulty; PCB faulty. Cycle is paused.
START/RESET 30 E42 Door lock unit faulty; Wiring faulty; PCB faulty. Current leakage from heating element to ground. Cycle is paused. START/RESET 32 E43 Door lock unit faulty; Wiring faulty; PCB faulty. (Safety drain cycle) Cycle stops. ON/OFF RESET 33 E44 PCB faulty. (Safety drain cycle) Cycle stops. ON/OFF RESET 34 E45 PCB faulty. (Safety drain cycle) Cycle stops. ON/OFF RESET 34 E51 PCB faulty; current leakage from motor or from wiring. Cycle blocked, door locked (after 5 attempts). RESET 35 E52 Motor faulty; wiring faulty; PCB faulty. Cycle blocked, door locked (after 5 attempts). RESET 36 E53 PCB faulty. Cycle blocked, door locked. RESET 40