electrolux EWM1100 — Electrolux EWM1100 — руководство по ремонту (EN)

Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. If there are traces of burning on the circuit board, refer to page 59 Tests to be performed: YES 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 25/59 599 70 32-47 E24: «Sensing» circuit of the component (triac) that controls the drain E24 E24 pump faulty E31 The analogic pressure switch is giving to the main board E31 a signal outside the range Measure a close circuit across J10-1,J10-2, J10-3 and the connector on analogic pressure switch (they are 3 independent connections see fig. 7. Is the cable between main board and analogic pressure switch OK and connected correctly on both sides?

Reconnect and/or replace the cable and restart the diagnostic cycle to check for further alarm conditions. NO d her the Scheda Elettronica the Replace the analogic pressure switch an restart the diagnostic cycle to check for furt alarm conditions. Does the appliance display alarm code again? d her the YES Replace the main circuit board and restart diagnostic cycle to check for further alarm conditions. the fig. 7 If there are burn marks on electronic board, see page 59