Tests to be performed: Clean/change the hoses and/or air trap system and repeat completely the diagnostic cycle to check for further alarm conditions. NO Check the draining system (filter, drain pump, drain hose). Is the machine draining correctly? Clean the draining system. NO YES YES Select a washing cycle. After few minutes did the machine fill with water and the motor is turning? Replace the analogic pressure switch and run again the diagnostic cycle to check for further alarm conditions. NO Appliance is OK. If there are traces of burning on the circuit board, refer to page 59 fig.
8 Fig.2 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 26/59 599 70 32-47 E32 The analogic pressure switch is giving an error during the calibration phase E32 (At the beginning of each cycle the appliance drain to empty the tub and create a 0 level to verify the calibration of the analogic pressure switch) Drain the water from the tub. Are pressure switch hose and air trap system free? (You can disconnect the hose and blow in it to check if the system is free) fig. 2 and 8 YES YES