electrolux EWM1100 — Electrolux EWM1100 — руководство по ремонту (EN)

Tests to be performed: Empty the machine. Are pressure switch hose and air trap system free? (You can disconnect the hose and blow in it to check if the system is free) -see fig. 2 and 8- Clean/change the hoses and/or air trap system and repeat completely the diagnostic cycle to check for further alarm conditions. NO YES Is the machine filling water when main switch is turned OFF? Get inside diagnostic cycle at step 8 . After door lock is the machine also filling water? Is the cable between main board and analogic pressure switch connected correctly on both sides? Reconnect and/or replace the cable and do the diagnostic cycle completely again to check for further alarm conditions.

NO NO NO YES YES YES Replace the inlet valves and repeat completely the diagnostic cycle to check for further alarm conditions. Replace the main board and repeat completely the diagnostic cycle to check for further alarm conditions. Replace the analogic pressure switch and run the diagnostic cycle to check for further alarm conditions. If there are traces of burning on the circuit board, refer to page 59 fig. 8 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 27/59 599 70 32-47 E35: Water level too high E35 E35 The electronic board measures a water level from analogic pressure switch higher then 300 mm for more then 15 seconds. Fig.2 Fig.2