electrolux EWM1100 — Electrolux EWM1100 — руководство по ремонту (EN)

Tests to be performed: Clean the air trap system and/or the pressure switch hose and run again the diagnostic cycle. NO NO Replace the analogic pressure switch and run again the diagnostic cycle to check for further alarm conditions. NO fig. 6 YES Check/replace the wiring and run the diagnostic cycle again to check for further alarm conditions. If there are traces of burning on the circuit board, refer to page 59 Fig.2 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 28/59 599 70 32-47 E38: Pressure chamber blocked E38 E38 The analogic pressure switch is not able to measure any variation of the water level for at least 30-sec. during drum movement. Get inside the diagnostic cycle and go to step 6.

Is the motor turning and the drum not moving? YES Change/refit the drive belt and run again the diagnostic cycle to check for further alarm conditions. Empty the machine. Verify the air trap system and the pressure switch hoses. Is the system free? -see fig.2- SI Measure across connector J7-2 and the machine structure and across connector J7-8 and the machine structure, are there any current leakage? -see fig.6- J7 J10 J9 J2 J1 U3 Fig.4 J7 J10 J9 J2 J1 U3 Fig.4 Fig.4 J10 J9