electrolux EWM1100 — Electrolux EWM1100 — руководство по ремонту (EN)

Tests to be performed: Replace the door interlock and restart the diagnostic cycle to check for further alarm conditions. To check the wiring, (with the door open), measure the following wiring connectors (fig. 4) : -between wires J1-3 and J1-1, the circuit must NOT be open (measure the resistive value of the PTC). - between wires J1-3 and J1-2, the circuit must be OPEN. NO NO YES Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. J7 J2 J1 U3 Fig.4 If there are traces of burning on the circuit 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 33/59 599 70 32-47 E43 E43:

Problems with the triac which actions the door interlock E43 Detach the connectors and effect measurement on the component (fig. 9): - across connectors 3 and 5 the circuit must NOT be open (the resistive value should be measurable). - across connectors 4 and 5, the circuit must be OPEN (the numbers are printed on the component). Is the door safety interlock OK? YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. J10 J9 Circuit board board, refer to page 59 ∞ Ω n Ω fig. 9 fig. 9