Tests to be performed: E52 will probably be displayed: replace the motor and restart the diagnostic cycle to check for further alarm conditions. NO If there are traces of burning on the circuit board, refer to page 59 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 35/59 599 70 32-47 E51: Motor power triac short-circuited E51 E51 Intervention of the safety system for short-circuiting of the triac (after 5 attempts during the cycle, immediately if detected at the start or during diagnostics) Measure among all the terminals of wiring connector J7-2÷J7-8 and the structure of the appliance see fig.6 Is there current leakage?
Reconnect the connector J7 to the circuit board, detach the connector from the motor and perform phase 8 of the diagnostic cycle. Does E51 alarm appear again? NO YES Detach the connector from the motor and measure across the terminals of the motor and the motor shield. -see fig.10- Is there current leakage? YES Replace the motor and restart the diagnostic cycle to check for further alarm conditions. YES fig. 6 fig. 10 fig. 10 J7 J10 J9 J2 J1 U3 Fig.4 J7 J10 J9 J2 J1 U3 Fig.4 J10 J9