Tests to be performed: NO Does the motor rotate for a few moments and then stop? NO The motor does not rotate at all. - see page 38 - YES Replace the motor or the tachometric generator and restart the diagnostic cycle to check for further alarm conditions. Measure across the terminals of the wiring connector J7-7 and J7-8. Are the values ( Ω ) of the tachometric generator correct? (refer to page 39 - Step 4, phase “A” ). Detach the connector from the motor and measure ( Ω ) the coil of the tachometric generator -see fig.11- Is the value correct? (refer to page 39 Step 4 - phase “A”). YES YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions.

Measure across the same terminals of the wiring connector (J7-7 and J7-8) and the structure of the appliance. Is there any current leakage? - see fig.6 - Check for the positioning of the tachometric generator. Is it correct? - see fig.12 - Replace the motor/ tachometric generator and restart the diagnostic cycle to check for further alarm conditions. NO YES YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. Replace the main circuit board and restart the diagnostic cycle to check for further alarm conditions. If there are traces of burning on the circuit board, refer to page 59 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 36/59 599 70 32-47 E52:

No signal from the motor tachometric generator (first part) E52 E52 Cycle blocked after 5 attempts during the cycle or immediately if detected at the start or during diagnostics. Perform phase 7 of the diagnostic cycle (the drum rotates at 55 rpm clockwise 55 rpm anti-clockwise with pulse at 250 rpm). Does the motor rotate correctly? YES The motor protection circuit-breaker has probably tripped.

Before replacing the motor, check the following → that the hydraulic circuit of the pressure switch is OK (minor leaks from the tube may cause greater than normal water fills, and the motor may overheat) → that the bearings are OK and the drum rotates without friction → that the mains voltage is correct (if the voltage is too low, though not lower than the EH3 alarm threshold, the motor might not start) Restart the diagnostic cycle to check for further alarm conditions. NO NO NO