Tests to be performed: The motor does not rotate at all. Replace the motor and restart the diagnostic cycle to check for further alarm conditions. NO 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 38/59 599 70 32-47 E52: No signal from the motor tachometric generator (second part) E52 E52 Cycle blocked after 5 attempts during the cycle or immediately if detected at the start or during diagnostics. To check the wiring, measure (Ω) across the following terminals of the circuit board connector (fig.4) and compare with the correct values (see page 39:
step 4 – motor parameters) - across J7-2 and J7-5, the value must be as in 4 - B (Stator) - across J7-1 and J7-5, if present, the value must be as in step 4 - D (stator ½ range). - across J7-2 and J7-4, the value must be as in step 4-C (rotor). Are these values correct? YES Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. Check the motor as described on page 39. Is the motor OK? NO YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. If there are traces of burning on the circuit board, refer to page 59 fig. 11 Circuit board 2 J1 J7 J10 J9 J2 J1 U3 Fig.4 2 J1 J 2