Procedure for checking the commutator motors N.B.: When checking the rotor winding, the measurement must be effected over the entire surface, rotating the spindle very slowly and checking for short-circuits between visible plates. Also check the brushes for wear. fig. 10 fig. 11 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 39/59 599 70 32-47 1) Check the connector blocks (wiring) and check for detached or bent terminals. 2) Check for traces, residue or deposits of water or detergent on the motor and identify the source. 3) Check for windings or other parts that may be grounded or poorly insulated. Use a tester with a minimum scale of 40 MΩ:
between each terminal and the casing, this should read ∞ (fig. 10). 4) Check each winding against the values shown in the table below (fig. 11). P = motor protector R = rotor S = stator T = tachometric generator MOTORS TERMINALS ON MOTOR TERMINAL BLOCK CHECKS: C.E.SET. [ ] ACC (FHP) ACC (SOLE) BSH ECM A 6-7 Winding of tachymetric generator 63÷74 125÷145 468÷540 14÷16 84÷98 171÷197 B 2-5 Stator winding (full range) 1.0÷2.0 0.9÷3.2 0.8÷1.9 1.4÷1.9 1.3÷1.6 C 3-4 Rotor winding (overheating breaker) 1.6÷2.7 0.5÷3.0 1.4÷2.3 1.5÷1.9 1.8÷2.5 D 1-5 Stator winding (half range, presence of terminal 1) 0.34÷0.65 0.4÷1.2 0.4÷1.0 1.0÷1.2 0.6÷0.8