Tests to be performed : Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. NO Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. NO If there are traces of burning on the circuit board, refer to page 59 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 41/59 599 70 32-47 E54: Motor relay contacts sticking E54 E54 Voltage in the motor circuit even when the motor should be inoperative Measure between all terminals of wiring connector J7-2 ÷ J7-8 and the structure of the appliance see page 39, point 3 Is there any current leakage? - see fig.
9 - YES Detach the connector from the motor and measure across the terminals and the motor shield. - see fig. 10 - Is there any current leakage? YES Replace the motor and restart the diagnostic cycle to check for further alarm conditions. Circuit board fig. 9 fig. 10 J7 J10 J9 J2 J1 U3 Fig.4 J7 J10 J9 J2 J1 U3 Fig.4 Fig.4 J10 J9