electrolux EWM1100 — Electrolux EWM1100 — руководство по ремонту (EN)

Tests to be performed: Measure the value of the NTC sensor across contacts J9-9 and J9-8 of the circuit board connector. Is the value correct? (between 5.7 and 6.3 K Ω at 20°C) YES Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 42/59 599 70 32-47 E61 E61: Insufficient heating during washing Maximum heating time exceeded E61 Â SOMETIMES THE ALARM CAN BE CAUSED BY THE POWER VOLTAGE TOO LOW! Detach the connector and measure the value directly on the NTC sensor. Is the value correct? - see fig.