Tests to be performed: NO Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. Detach the connector and measure directly on the NTC sensor. - see fig. 14 - Is the value correct? (between 5.7 and 6.3 K Ω at 20°C) Replace the NTC sensor and restart the diagnostic cycle to check for further alarm conditions. NO YES fig. 15 Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. fig. 14 Circuit board 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 43/59 599 70 32-47 E62:
Overheating during washing E62 E62 The temperature of the NTC sensor exceeds 88°C for more than 5 minutes Start the diagnostic cycle and fill with water up to the level of the door to ensure that the heating element is completely dipped into. Measure between wiring connector J2-2 and the structure of the appliance - see fig 6 - Is the circuit open? YES Measure the NTC sensor across terminals J9-9 and J9-8 of the circuit board connector. Is the value correct? (between 5.7 and 6.3 KΩ at 20°C) YES Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. Detach the connector and measure across the heating element and the ground contact. - see fig.
15 - Is the circuit open? Replace the heating element and restart the diagnostic cycle to check for further alarm conditions. NO YES NO If there on the are traces of burning circuit board, refer to page 59