Tests to be performed: 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 44/59 599 70 32-47 E66: The contacts of the heating element power relay are always E66 E66 closed Measure across connector J2-1/J2-2 on the circuit board and the structure of the appliance. (Fig. 6) Is there any current leakage? YES Detach the connector and measure across the heating element and the ground contact. - fig. 15 - Is the circuit open? YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. Measure across connector J2-1/J2-2 on the circuit board and the structure of the appliance. (Fig. 6) Is there any current leakage?
Detach the connector and measure across the heating element and the ground contact. - fig. 15 - Is the circuit open? YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. fig. 6 J7 J10 J9 J2 J1 U3 Fig.4 fig. 15 Circuit board fig. 6 fig. 6 J7 J10 J9 J2 J1 U3 Fig.4 Fig.4 fig. 15 fig. 15 NO NO J10 J9