electrolux EWM1100 — Electrolux EWM1100 — руководство по ремонту (EN)

Tests to be performed : Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 45/59 599 70 32-47 E68 E68: Washing heating element leaks current E68 Start the diagnostic cycle and fill with water up to the level of the door to ensure that the heating element is completely dipped into. Measure between wiring connector J2-1/J2-2 and the structure of the appliance -see fig.6- Is the circuit open? Detach the connector and measure across the heating element and the ground contact. - see fig. 15 - Is the circuit open?

Replace the heating element and restart the diagnostic cycle to check for further alarm conditions, NO NO YES If there are traces of burning on the circuit board, refer to page 59 fig. 6 fig. 6 fig. 15 fig. 15 J7 J10 J9 J2 J1 U3 Fig.4 J10 J9