Tests to be performed: 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 46/59 599 70 32-47 E69 E69: Washing heating element interrupted E69 Measure the heating element value (Ω) across terminals J2-2 ÷ J2-1of the wiring connector. -see fig.4- Is the value correct? (26÷28Ω for 230V/1950W, 28÷31 for 240V/1950W) Measure the ohmic value directly on the terminals of the heating element (detach the connectors) -see fig 13- Is the value correct? (26÷28Ω for 230V/1950W, 28÷31 for 240V/1950W) Replace the heating element and restart the diagnostic cycle to check for further alarm conditions. NO NO YES Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions.
Fig.13 J7 J10 J9 J2 J1 U3 Fig.4 J10 J9 J2 J1