Tests to be performed: YES NO cycle to check for further alarm conditions. NO Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. If there are traces of burning on the circuit board, refer to page 59 J7 J2 J1 fig. 6 U3 Fig.4 fig. 14 Circuit board 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 47/59 599 70 32-47 E71: NTC washing sensor faulty E71 E71 Voltage not within limits (short-circuited or open) Perform phase 6 of the diagnostic cycle and wait until the fill ends. Switch the appliance off and measure the value of the NTC sensor across contacts J9-8 and J9-9 dof the wiring connector -see fig. 4-. Is the value correct?
(between 5.7÷6.3 KΩ at 20°C) Detach the connector and measure the NTC sensor directly. - see fig. 14 - Is the value correct? (5.7÷6.3 KΩ at 20°C) Replace the NTC sensor and restart the diagnostic cycle to check for further alarm conditions. NO NO YES Check/replace the wiring and restart the diagnostic cycle to check for further alarm conditions. Measure across terminals J9-9, J9-8 of the connector and the structure of the appliance – see fig. 6 - Is there any current leakage? YES Detach the connector and measure directly across the terminals of the NTC sensor and the structure of the appliance (there must be water in the tub). Is there any leakage?
YES Replace the NTC sensor and restart the diagnostic cycle to check for further alarm conditions. J10 J9