Tests to be performed: Is the sensor correctly positioned? -see fig.17- Position the sensor again into its seat and restart the diagnostic cycle to check for further alarm conditions. YES Measure the value of the NTC sensor (5.7ч6.3K Ω at 20°C) across contacts J9- 8 and J9-9 of the wiring connector (fig. 4). Is the value correct? Replace the sensor and restart the diagnostic cycle to check for further alarm conditions. 2007-10 SOI/DT-mdm FCPD-dp Quality-fz 48/59 599 70 32-47 E74 E74: NTC sensor wrongly positioned E74 NO NO Perform phase 6 of the diagnostic cycle and wait until the fill ends. Remain in this phase for five minutes.

Switch the appliance off and measure the value of the NTC sensor across contacts J9-8 and J9-9 of the wiring connector (fig. 4). Is the value lower than 5 KΩ? !!ATTENTION!! DRAIN WATER FROM TUB BECAUSE IT IS BOILING YES Replace the circuit board and restart the diagnostic cycle to check for further alarm conditions. Fig.4 Circuit board Fig.17 J10 J9