A.D.L. 10 / 2010 17/26 Malfunction in electronic pressure switch circuit ѓ Wiring; Electronic pressure switch. ѓ Main circuit board. ѓ Motor belt broken. ѓ Pressure switch hydraulic circuit clogged. Description Possible fault ѓ Drain tube kinked/clogged/improperly positioned. ѓ Solenoid valve faulty. ѓ Drain filter clogged/dirty. ѓ Drain pump faulty. ѓ Leaks from pressure switch water circuit. ѓ Pressure switch defective; ѓ Wiring; main circuit board. ѓ Water fill solenoid valve faulty. ѓ Leaks from pressure switch water circuit. ѓ Faulty wiring. ѓ Pressure switch faulty. ѓ Main circuit board faulty.

Calibration error of the electronic pressure switch Internal pressure chamber is clogged (water level does not change for at least 30 sec. of drum rotation) Overflow ALARM CODE E31 E32 E35 E38 ALARM CODE Action Description Possible fault Reset Machine status E31 Malfunction in electronic pressure switch circuit ƒ Wiring; Electronic pressure switch. ƒ Main circuit board. Cycle stops with door locked RESET E32 Calibration error of the electronic pressure switch ƒ Drain tube kinked/clogged/improperly positioned. ƒ Solenoid valve faulty. ƒ Drain filter clogged/dirty. ƒ Drain pump faulty. ƒ Leaks from pressure switch water circuit. ƒ Pressure switch defective; ƒ Wiring; main circuit board.

Cycle paused START/RESET E35 Overflow ƒ Water fill solenoid valve faulty. ƒ Leaks from pressure switch water circuit. ƒ Faulty wiring. ƒ Pressure switch faulty. ƒ Main circuit board faulty. Cycle interrupted. Safety drain cycle. Drain pump continues to operate (5 min. on, then 5 min. off etc.) RESET E38 Internal pressure chamber is clogged (water level does not change for at least 30 sec. of drum rotation) ƒ Motor belt broken. ƒ Pressure switch hydraulic circuit clogged. Heating phase is skipped RESET