A.D.L. 10 / 2010 18/26 Faulty sensing by door delay system ѓ Main circuit board faulty. Faulty sensing by door delay system triac ѓ Main circuit board faulty. Description Possible fault ѓ Faulty wiring. ѓ Door safety interlock faulty. ѓ Electrical current leak between heating element and ground. ѓ Main circuit board faulty. ѓ Check whether the door is closed properly ѓ Faulty wiring. ѓ Door safety interlock faulty ѓ Main circuit board faulty. ѓ Faulty wiring. ѓ Door safety interlock faulty. ѓ Main circuit board faulty.
Faulty triac supplying power to door delay system Problems with door lock Door open ALARM CODE E41 E42 E43 E44 E45 ALARM CODE Action Description Possible fault Reset Machine status E41 Door open Check whether the door is closed properly Faulty wiring. Door safety interlock faulty Main circuit board faulty. Cycle paused CLOSED THE DOOR E42 Problems with door lock Faulty wiring. Door safety interlock faulty. Electrical current leak between heating element and ground. Main circuit board faulty. Cycle paused START/RESET E43 Faulty triac supplying power to door delay system Faulty wiring. Door safety interlock faulty. Main circuit board faulty. Safety drain cycle.
Cycle blocked RESET E44 Faulty sensing by door delay system Main circuit board faulty. Safety drain cycle. Cycle blocked RESET E45 Faulty sensing by door delay system triac Main circuit board faulty. Safety drain cycle. Cycle blocked RESET