User Manual EM303B General Purpose Inverter rcentage of analog input terminal. t.ion scale (F7-02) continuously for certain time.his monotonic decreasing is active, the actual disabled point of ADT1=Analog ADT1 (F7-05)- Analog ADT1 Hysteresis(F7-06), i.e. if input voltage of analog input terminal VF=2V (10V=Analog ADT1 (og input terminal VF>2.5V ( VF/V 2.5 Hysteresis 2 0 ADT1 Time(s) Figure 7-24 ADT Function F7-07 ~ F7-10 Setting method of analog ADT2 and analog ADT3 parameters is the same as that of analog ADT1. 8.9.3 Jog Analog Output 0 Disabled Disabled Enabled Time(s) In jog running mode, M0/M1 output can be switched as different meanings from normal running.

Analog output gain and the upper and lower limit are only for M0/M1, and not related to present running status. F7-14~F7-15 Jog output analog output upper limit and lower limit are for limiting the analog output in jog running mode. F7-16 Jog output gain is for analog output signal proportional zooming in jog running status. 8.9.4 Carrier 131 No. Function Range Unit Default Type F7-11 Jog M0 Output Lower Limit 0.00~100.00 % 0.00 ● F7-12 Jog M0 Output Upper Limit 0.00~100.00 % 100.00 ● F7-13 Jog M0 Output Gain 0.00~300.00 % 95.00 ● F7-14 Jog M1 Output Lower Limit 0.00~100.00 % 0.00 ● F7-15 Jog M1 Output Upper Limit 0.00~100.00 % 100.00 ● F7-16 Jog M1 Output Gain 0.00~300.00 % 95.00 ● No.

Function Range Unit Defaul t Type F7-20 Automatic PMW 0: Disabled 1: Enabled 0 ● F7-21 Lower Limit Carrier Frequency 1.000~F7-22 kHz 2.000 ● Upper Limit Carrier Frequency 0~9kW:1.000~16.000 9kW~37kW:1.000~8.000 37kW~110kW:1.000~4.000 110kW~400kW: 1.000~3.000 kHz 6.000 ● F7-22