User Manual EM303B General Purpose Inverter 6.2.3 F2 Group: Input/Output Terminal Parameters 56 No. Function Range Unit Default Type S/N F1-25 Analog Input Gain K4 0.00~600.00 % 0.00 ● 57 F1-26 Analog Input Gain K5 0.00~600.00 % 0.00 ● 58 F1-27 Analog Input Gain K6 0.00~600.00 % 0.00 ● 59 F1-28 Analog Input Gain K7 0.00~600.00 % 0.00 ● 60 F1-29 Analog Input Gain K8 0.00~600.00 % 0.00 ● 61 F1-30 Communication Overtime 0.0~60.0(0.0: Disabled) S 0.0 ● 62 Master Communication Transmitting Data 0: Input frequency 1: Output frequency 2: Primary Numeric Frequency 3: Auxiliary Numeric Frequency 4: VP 5: VS 6: VF 7: IS 8: IF 0 ● 63 F1-31 No.
Function Range Unit Default Type S/N F2-00 Multi-function Input Terminal X1-RUN See Table 6-1 Functions of Numeric Multi-function Input Terminals 1 〇 64 F2-01 Multi-function Input Terminal X2-F/R 2 〇 65 F2-02 Multi-function Input Terminal X3-D1 3 〇 66 F2-03 Multi-function Input Terminal X4-D2 4 〇 67 F2-04 Multi-function Input Terminal X5-D3 5 〇 68 F2-05 Multi-function Input Terminal X6-FRS 9 〇 69 F2-06 Multi-function Input Terminal X7-RST 10 〇 70 F2-07 Not used 71 F2-08 VS Input Function Defining 0 〇 72 F2-09 IS Input Function Defining 0 〇 73 F2-10 VF Input Function Defining 0 〇 74 F2-11 IF Input Function Defining 0 〇 75 F2-12 Multi-function Output Terminal Y1 See Table 6-2 Functions of Numeric Multi-function Output Terminals 0 〇 76 F2-13 Multi-function Output Terminal Y2 1 〇 78 F2-14 Relay Output Terminal R1 9 〇 79 F2-15 Not Used 80 F2-16 Analog Output Terminal M0 See Table 6-3 F2-16~F2-17 Analog Output Full Scale % 0 〇 81 F2-17 Analog Output Terminal M1 % 6 〇 82 F2-18 Not Used 83 ~86 ~F2-21 F2-22 M0 Output Lower Limit 0.00~100.00 % 0.00 ● 87 F2-23 M0 Output Upper Limit 0.00~100.00 % 100.00 ● 88 F2-24 M0 Output Gain 0.00~300.00 % 95.00 ● 89 F2-25 M1 Output Lower Limit 0.00~100.00 % 0.00 ● 90