User Manual EM303B General Purpose Inverter RUN F/R Xi f Output Frequency -f ( a ) F0 - 05=2 3-wire sequence ( b ) F0 - 20=0 , F0 - 05=2 Forward/Reverse running sequence RUN F/R Xi Output Frequency f -f Time ( c ) F0 - 05=3 3-wire sequence ( d ) F0 - 20=0, F0 - 05=3 Forward/Reverse running sequence Figure 7-3 3-Wire Sequence Please use the buttons and switches correctly by following the mode illustrated in the above diagrams of EM303B 3-wire sequences, otherwise, malfunctions may occur. 85 Time PLC 24V EM303B RUN Inverter F/R Xi COM Forward Reverse Stop PLC 24V EM303B RUN Inverter F/R Xi COM Run Forward/Reverse Stop No. Function Range Unit Default Type Regular Speed Setting Mode 0:

Primary Numeric Frequency 1: VP 2: VS 3: IS 4: Not Used 5: K3*VS+K4*IS 6: K3*VS+K5*VF 7: K4*IS+K6*IF 8: MAX{K3*VS,K5*VF} 9: MAX{K4*IS,K6*IF} 10:K1*VP+K2*(K3*VS+K4*IS+K5*VF+K6*IF-K8*5V ) 1 〇 F0-06