sinee — 7.1 F00 Group: General Parameter

EM500 Open-Loop Vector Control Inverter User Manual F00.05=4: AI4 (Expansion Card) Auxiliary frequency source B is determined through AI (percentage) * F00.16. F00.05=5: High-Frequency Pulse Input (X7) Auxiliary frequency source B is determined through HDI (percentage) * F00.16. Please refer to the description of F00.04 for detailed explanations of AI1-AI4 and X7. F00.04 has the same meanings as AI1-AI4 and X7. 100.00% is the percentage inputted through F00.16 (Maximum Frequency). F00.05=6 or 7:

Auxiliary Frequency Setting by Communication For master-slave communication (F10.05=1) and the inverter is slave (F10.06=0) auxiliary frequency source B is set as “700FH (Main Frequency Setting by Communication) * F00.16 (Maximum Frequency)* F10.08 (Receiving Proportionality Factor of Slave)”. The range of 700FH is -100.00% to 100.00%. See Table 12-2 for details. For general communication (F10.05=0): a) F00.05=6 Auxiliary Frequency Communication Percentage Setting. Auxiliary frequency source A is set as “7002H (communication setting of auxiliary channel frequency B) * F00.16 (Maximum Frequency)”. b) F00.05=7 Auxiliary Frequency Communication Direct Setting.

Auxiliary frequency source B is set as “7016H (communication setting of auxiliary channel frequency B)”. (Maximum Frequency). See Table 12-2 for details. The range of 7002H is -100.00% to 100.00%. The range of 7016H is 0.00 to F00.16 F00.05=8: digital Potentiometer For speed mode auxiliary frequency source B is set as digital Potentiometer. F12.42 is the frequency setting by digital potentiometer. If F12.12=1 the frequency setting by digital potentiometer is saved in EEPROM after power off. F00.05=10: Process PID Auxiliary frequency B is determined by the output of Process PID (refer to 7.10). 159