sinee — 7.2 F01 Group: Motor 1 Parameter

EM500 Open-Loop Vector Control Inverter User Manual F01.09 - F01.13 are parameters of synchronous motor. However, user can not get these parameters generally. Please autotuning motor parameters by F01.34. User must set the parameters of F01.00 - F01.08 as per actual conditions before motor parameter autotuning and make sure to select a proper type of motor (F01.00=2). 174 No.

Function Range Unit Default Type F01.19 Stator Resistor of Synchronous Motor 1 - 60000 (Motor Rated Power ≤ 75kW) 0.1 - 6000.0 (Motor Rated Power >75kW) mΩ Up To Specific Model 〇 F01.20 d-Shaft Inductance of Induction Motor 0.01 - 600.00 (Motor Rated Power ≤ 75kW) 0.001 - 60.000 (Motor Rated Power >75kW) mH Up To Specific Model 〇 F01.21 q-Shaft Inductance of Synchronous Motor 0.01 - 600.00 (Motor Rated Power ≤ 75kW) 0.001 - 60.000 (Motor Rated Power >75kW) mH Up To Specific Model 〇 F01.22 Counter Electromotive Force of Synchronous Motor 10.0 - 2000.0 (Counter Electromotive Force of Rated Rotation Speed) V Up To Specific Model 〇 F01.23 Initial Electric Angle of Synchronous Motor 0.0 - 359.9 (Synchronous motor enabled) 〇 No.

Function Range Unit Default Type F01.34 Motor Parameter Autotuning 0: No Autotuning 1: Stationary Autotuning of Induction Motor 2: Rotational Autotuning of Induction Motor 11: Stationary Autotuning of Synchronous Motor 12: Rotational Autotuning of Synchronous Motor 0 〇