sinee — 7.2 F01 Group: Motor 1 Parameter

EM500 Open-Loop Vector Control Inverter User Manual parameters of F01.09 - F01.13. Please pay attention. User must set the parameters of F01.00 - F01.08 as per actual conditions before motor parameter autotuning. Meanings of motor parameters are illustrated in Figure 7–6: R1 L1-Lm R2 L2-Lm I1 I2 U1 (1-s)/s*R2 I0 Lm Figure 7–6 Induction Motor Stable Equivalent Model rotor resistor, rotor inductance, stator & rotor mutual inductance, and idling excitation In the figure, R1, L1, R2, L2, Lm and I0 refer to stator resistor, stator inductance, current respectively. The field weakening factor of induction motor will be automatically set in motor parameter autotuning.

User does not need to set these factors. 173 Function Name of Function Prope Parameter Description Unit Default Code Code rty F01.14 Induction Motor Field Weakening Factor 1 10.00 - 100.00 % 87.00 〇 F01.15 Induction Motor Field Weakening Factor 2 10.00 - 100.00 % 80.00 〇 F01.16 Induction Motor Field Weakening Factor 3 10.00 - 100.00 % 75.00 〇 F01.17 Induction Motor Field Weakening Factor 4 10.00 - 100.00 % 72.00 〇 F01.18 Induction Motor Field Weakening Factor 5 10.00 - 100.00 % 70.00 〇