EM500 Open-Loop Vector Control Inverter User Manual 183 Frequency Source to AI3 55 Switch Main Frequency Source to High-Frequency Pulse Input 56 Switch Main Frequency Source to Communication Setting 57 Inverter Enabled If inverter meets other running conditions and this terminal is enabled, then inverter can run; otherwise, inverter can not run if inverter meets other running conditions but this terminal is disabled. ★ Enable inverter: if no terminal option is selected, the default is enabled; if there is only one terminal option, the selected terminal status works; if there are more than one terminal, this terminal will be disabled as long as one of the selected terminals is disabled.
57~78 Not Used 79 Remote Start Air compressor Special Function,set as air compressor applications (F16.00 = 2) and the remote control (F28.01 = 1).When the inverter is not running, remote control is closed and the system restarts, disconnected and the system shutdown. If the inverter has started in the other way, the function will be invalid. 80 Power Frequency Conversion When F16.12 = 3 (Phase sequence phase card) and selection for the manual switch (F15.45 = 1), if the phase sequence detected meets the switching condition, then close this function terminal and it can be switched, otherwise it can not be switched.
81~88 Not Used 89 Feedforward Reset Winding application-specific function, close the terminal ,feedforward value will be reset to the starting feedforward