EM500 Open-Loop Vector Control Inverter User Manual acceleration/deceleration time and overall running time for preset speed 1 - 15, In simple PLC running, user can set running frequency, running direction, respectively. Let’s take preset speed 13 (last one) as an example; its specific running conditions are shown in Figure 7-26. F08.12=50.00 : The running frequency for preset speed 13 is 50.00 Hz; F08.43=31: A t preset speed 13, inverter runs reversely and acceleration/deceleration is controlled by acceleration/deceleration time 4 (F15.07/F15.08); F08.44=5.0 : Running Time of Preset Speed 13 is 5.0s (default setting: F08.18=0). 239 2: Acceleration/Deceleration Time 3 3:
Acceleration/Deceleration Time 4 F08.44 Running Time of Preset Speed 13 0.0 - 6000.0 5.0 ● F08.45 Setting of Preset Speed 14 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3: Acceleration/Deceleration Time 4 0 ● F08.46 Running Time of Preset Speed 14 0.0 - 6000.0 5.0 ● F08.47 Setting of Preset Speed 15 Ones Place: Running Direction 0: Forward 1: Reverse Tens Place: Acceleration/Deceleration Time 0: Acceleration/Deceleration Time 1 1: Acceleration/Deceleration Time 2 2: Acceleration/Deceleration Time 3 3:
Acceleration/Deceleration Time 4 0 ● F08.48 Running Time of Preset Speed 15 0.0 - 6000.0 5.0 ●