EM500 Open-Loop Vector Control Inverter User Manual due to the feedback disconnection. The setting depends upon the nature of the feedback PID feedback disconnection detection function can be used to prevent a slip accident sensor. value. When the feedback is less than the value set through F09.25 and this status is If 0.01% sensor is fed back at disconnection, it’s required to set F09.25 as a proper maintained for PID Feedback Disconnection Detection Time (F09.26), it is deemed as a PID feedback disconnection. If 100.0% sensor is fed back at disconnection, it’s required to set F09.24 as a proper value.
When the feedback is greater than the value set through F09.24 and this status is maintained for PID Feedback Disconnection Detection Time (F09.26), it is deemed as a PID feedback disconnection. ★ Once the feedback sensor is determined, only corresponding detection mode is enabled, either upper limit detection or lower limit detection, other than both. 248 Value of PID Feedback Disconnection 100.00=Feedback Disconnection Disabled F09.25 Lower Limit Detection Value of PID Feedback Disconnection 0.00 - 100.00 0.00=Feedback Disconnection Disabled % 0.00 ● F09.26 PID Feedback Disconnection Detection Time 0.000 - 30.000 s 0.000 ● No. Function Range Unit Default Type F09.27 PID Sleep Control 0:
Disable 1: Enable 2: Lower Limit Frequency Enable 3: No Output Enable 0 ● F09.28 Sleep Action Point 0.00 - 100.00 (100.00 corresponds to PID Setting Feedback Range ) % 100.00 ● F09.29 Sleep Delay Time 0.0 - 6500.0 s 0.0 ● F09.30 Awakening Action Point 0.00 - 100.00 (100.00 corresponds to PID Setting Feedback Range ) % 0.00 ● F09.31 Awakening Delay Time 0.0 - 6500.0 s 0.0 ●