sinee — 7.13 F12 Group: Keypad and Display Parameter

EM500 Open-Loop Vector Control Inverter User Manual F12.32=1, Monitor mode 1. LED switching display and LCD small line (7 lines) Display function code is determined by F12.33 ~ F12.37 settings, Function code can be selected arbitrarily. F12.33 = 18.00, it means to select display F18.00 function code. LCD large display function code selection,F12.38=18.00, It shows the first line display the F18.00 function code. LCD large display mode is the default value, a screen can monitor F18.00, F18.06 and F18.09 three function codes. ★ LCD keyboard small row and large row display switch as shown below ENTER ESC LCD Keypad Refer to the LCD Keypad User's Manual for operation.

Refer to Section 4 of Chapter 4 for the monitor mode selection. The UP / DOWN function is enabled, When F12.41 = 0, the UP / DOWN function will not reverse when the inverter output frequency reduce to 0, When F12.41 = 1, the UP / DOWN function will reverse running when the inverter output frequency reduce to 0. 272 No. Function Range Unit Default Type F12.38 LCD display parameter 1 0.00~99.99 18.00 ● F12.39 LCD display parameter 2 0.00~99.99 18.06 ● F12.40 LCD display parameter 3 0.00~99.99 18.09 ● No. Function Range Unit Default Type F12.41 UP/DOWN cross zero option 0:forbidden 1:allowed 0 〇 No. Function Range Unit Default Type F12.42 Digital potentiometer 0.00~F00.16 Hz 0.00 ×