EM500 Open-Loop Vector Control Inverter User Manual 7.20 F19 Group: Fault Record Parameter This group of parameters can be used for viewing the types of the last three faults and the status of inverter at fault, but cannot be operated. Function codes related to the information about the last fault: 307 high-speed pulse input channel HDI (X7). See F16.03 and F16.04. Range: 0 - F16.03. F18.34 Actual Length Used to display the actual length of the workpiece being processed (by transformation from HDI (X7) as per relevant setting) of input pulses of present high-speed pulse input channel HDI (X7). See F16.01 and F16.02. Range: 0 - F16.01.
m F18.35 Remaining Time of Timed Run Used to display the remaining time of the timed run. See F16.05. Range: 0.0 - F16.05. min F18.36 Position of Rotor of Synchronous Motor Position of rotor of synchronous motor. Range: 0.0 - 359.9. ° F18.37 Rotary Transformer Position Used to display the rotary transformer position. Range: 0 - 4095. F18.38 Motor Temperature Used to display motor temperature collected by the analog channel 4 (AI4). Range: 0 - 200. ℃ F18.39 VF Separation Target Voltage Used to display VF separation target voltage in real time. Range: 0.0 - Motor Rated Voltage. V F18.40 VF Separation Output Voltage Used to display VF separation output voltage in real time. Range:
0.0 - Motor Rated Voltage. V F18.41 - F18.50 Not Used -100.0 ~ 100.0 F18.51 PID Output In zero servo running status, this function code is used to display present position offset. Range: -0 - 65535. % F18.60 Inverter temperature Temperature of inverter module ( it is normal that the temperature is higher than the environment for 40) - 40 ~ 200 ℃ No. Function Range Unit Default Type F19.00 Last Fault Type Display the last fault type. See Table 7-22 Fault Types 0 × F19.01 Output Frequency Used to display output frequency Hz 0.00 ×