EM500 Open-Loop Vector Control Inverter User Manual By manually resetting the factory settings, the parameters of the inverter will be restored to the parameters special for the compressor 338 0: Application of air compressor No explain all-in-one macros Set F 16.00 = 2, and select the macro, restore factory settings. The application parameters are automatically set to the following defaulted values The basic parameters (motor parameters need to be set manually, and make static autotuning for the motor parameters) F00.02 Command Source Options 2: Communication Control F00.05 Auxiliary Frequency Source B Options 10:Air compressor integrated PID F00.06 Frequency Source Options 1:

Auxiliary Frequency Source B F00.17 Upper Limit Frequency Control Options 200.00Hz F00.18 Upper Limit Frequency 200.00Hz F00.23 Carrier Frequency 4.0k F02.03 X4 79: Remote Start F02.04 X5 23: External Fault Input F02.05 X6 9: Coast to Stop F02.37 Minimum Input of Curve 2 2.20V F03.00 Y1 49: Inlet Valve Control F03.02 R1 50: Fan Start-stop Control Signals F03.03 R2 1:Inverter Running (RUN) F03.21 M1 38: The Fan Speed Output F06.29 Injection Current at Low Frequency Range 40.0%