sinee — 7.24 F28 Air Compressor Application

EM500 Open-Loop Vector Control Inverter User Manual This function code is used to display the running time, not save in case of power outage. This function code is used to display the physical value detected by the three sensors. Used to display the actual using time of each component. Used to display the cumulative loading and unloading ratio. Used to display the cumulative power consumption, saved in case of power outage. Used to check the cumulative running time. 350 No. Function Range Unit Default Type F28.78 Pressure feedback 0.00~600.00 MPa 0 × oil passage F28.79 temperature 0.0~200.0 ℃ 0 × feedback Motor temperature F28.80 0.0~200.0 ℃ 0 × feedback No.

Function Range Unit Default Type Oil filter actual F28.81 0~9500 h XXX ● using time Oil separator F28.82 0~9500 h XXX ● actual using time Air filter actual F28.83 0~9500 h XXX ● using time Lubricating oil F28.84 0~9500 h XXX ● actual using time Grease actual F28.85 0~9500 h XXX ● using time No. Function Range Unit Default Type Loading running F28.86 0~65535 h XXX ● time unloading running F28.87 0~65535 h XXX ● time No. Function Range Unit Default Type The cumulative F28.88 power meter: 0~65535 MWh XXX ● MWh The cumulative F28.89 0.0~999.9 KWh XXX ● power meter: KWh No. Function Range Unit Default Type Cumulative F28.90 0~60000 h XXX ● operation time