sinee — 12.3.3.20x41Write single register or command (not to save)

EM500 Open-Loop Vector Control Inverter User Manual Telling from the returned data, inverter has suffered 17 (0011H): abnormal failure of the temperature sensor. At the time, there are output frequency 0.00 Hz, output current 0.00 A, bus voltage 300 V (012CH), acceleration/deceleration status (standby) and working hours 0 hour. ★ The present function code 0x03 of MODBUS protocol supports “cross-group read of multiple function codes”; but user is not recommended to do cross-group read, so that user’s application does not need to upgrade after we upgrade our products.

12.3.3.20x41Write single register or command (not to save) This function code can be used to write single non-holding register in a remote device. Request PDU describes the address of the written register. Normal response is a response to the request and returned after writing the register  Request PDU  Response PDU 385 (F19.03) Register Value Lo 2C (F19.03) Register Value Hi 00 (F19.04) Register Value Lo 00 (F19.04) Register Value Hi 00 (F19.05) Register Value Lo 00 (F19.05) Function Code 1 byte 0x41 Register Address 2 bytes 0x0000 - 0xFFFF Register Address 2 bytes 0x0000 - 0xFFFF Function Code 1 byte 0x41 Register Address 2 bytes 0x0000 - 0xFFFF Register Value 2 bytes 0x0000 - 0xFFFF