sinee — 12.3.3.30x42Write multiple registers or commands (not to save)

EM500 Open-Loop Vector Control Inverter User Manual  Incorrect PDU (7001H) to “-50.00%”.: The following is an example of a request for changing the main frequency source A ★ The function code cannot be used to change the parameters of “○” property (unavailable to be modified during inverter running), i.e., user may only operate the parameters of “●” properly (available to be modified during inverter running). If user tries to modify the “○” property, an error code 1 will be returned. 12.3.3.30x42Write multiple registers or commands (not to save) This function code is used to write continuous non-holding register blocks (1 to 16 registers) in a remote device.

The value requested for writing is described in the request data field. Each register divides the data into two bytes. Normal response shall return function, initial address and number of registers written.  Request PDU 386 Error Code 1 byte 0xC1 Exceptional Code 1 byte See Table 12–4 Request Response Field Name (0x) Field Name (0x) Field Name (0x) (normal) (abnormal) Function 41 Function 41 Function C1 Register Address 70 Register 70 03 Hi Address Hi Exceptional Register Address 01 Register 01 Code Lo Address Lo Register Value Hi EC Register Value EC Hi Register Value Lo 78 Register Value 78 Lo Function Code 1 byte 0x42 Initial Address 2 bytes 0x0000 - 0xFFFF