EM500 Open-Loop Vector Control Inverter User Manual N*=Number of Registers Response PDU Incorrect PDU The following is an example of a request for setting acceleration time 1 (F00.14) as 5.00 and deceleration time 1 (F00.15) as 6.00:
387 Number of Registers 2 bytes 1 - 16 Number of Bytes 1 byte 2×N* Register Value N*×2 bytes Function Code 1 byte 0x42 Initial Address 2 bytes 0x0000 - 0xFFFF Number of Registers 2 bytes 1 - 16 Error Code 1 byte 0xC2 Exceptional Code 1 byte See Table12-4 Request Response Field Name (0x) Field Name (0x) Field Name (0x) (Normal) (abnormal) Function 42 Function 42 Function C2 Initial Address Hi 00 Initial Address 00 03 Hi Exceptional Initial Address Lo 0E Initial Address 0E Code Lo Number of Registers 00 Number of 00 Hi Registers Hi Number of Registers 02 Number of 02 Lo Registers Lo Number of Bytes 04 Register Value Hi 01 (F00.14) Register Value Lo F4 (F00.14) Register Value Hi 02 (F00.15) Register Value Lo 58 (F00.15)