sinee — 12.5 Example

EM500 Open-Loop Vector Control Inverter User Manual Change the setting frequency (for example 50.00 Hz/1388 H) (F00.04=7) Send: 01 41 70 15 13 88 3B 97 Return: 01 41 70 15 13 88 3B 97 (Normal) Return: 01 C1 04 70 53 (When abnormal, assuming that slave fails) 1) Read the last fault information (read F19.00 - F19.05) Send: 01 03 13 00 00 06 C1 4C Return: 01 03 0C 00 11 00 00 00 00 01 2C 00 00 00 0053 5B (Normal) Return:

01 83 04 40 F3 (When abnormal, assuming that slave fails) 408 7 CRC Parity Lo 66 CRC Parity Lo 66 8 CRC Parity Hi C7 CRC Parity Hi C7 * Frame End ≥3.5 idle characters Send Normal return Abnormal return * Frame Header ≥3.5 idle characters 1 Address 01 Address 01 Address 01 2 Function Code 41 Function Code 41 Function Code C1 3 Register Address 70 Register Address 70 Exceptional 04(assumption) Hi Hi Code 4 Register Address 15 Register Address 15 CRC Parity Lo 70 Lo Lo 5 Register Value Hi 13 Register Value Hi 13 CRC Parity Hi 53 6 Register Value Lo 88 Register Value Lo 88 7 CRC Parity Lo 3B CRC Parity Lo 3B 8 CRC Parity Hi 97 CRC Parity Hi 97 * Frame End ≥3.5 idle characters Send Normal return Abnormal return * Frame Header ≥3.5 idle characters 1 Address 01 Address 01 Address 01 2 Function Code 03 Function Code 03 Function Code 83 3 Initial Address 13 Number of Bytes 0C Exceptional 04(assumption) Hi Code 4 Initial Address 00 Register Value Hi 00 CRC Parity Lo 40 Lo (F19.00) 5 Number of 00 Register Value Lo 11 CRC Parity Hi F3 Registers Hi (F19.00)