EM500 Open-Loop Vector Control Inverter User Manual Return: 01 41 70 0000 01 E6 C5 (Normal) Return: 01 C1 04 70 53 (When abnormal, assuming that slave fails) 2) Inverter coast to stop Send: 01 41 70 0000 07 66 C7 Return: 01 41 70 0000 07 66 C7 (Normal) Return:
01 C1 04 70 53 (When abnormal, assuming that slave fails) 407 Send Normal return Abnormal return * Frame header ≥3.5 idle characters 1 Address 01 Address 01 Address 01 2 Function Code 41 Function Code 41 Function Code C1 3 Register Address 70 Register Address Hi 70 Exceptional 04(assumpti C o d e Hi 4 Register Address 00 Register Address Lo 00 CRC Parity Lo 70 Lo 5 Register Value Hi 00 Register Value Hi 00 CRC Parity Hi 53 6 Register Value Lo 01 Register Value Lo 01 7 CRC Parity Lo E6 CRC Parity Lo E6 8 CRC Parity Hi C5 CRC Parity Hi C5 * Frame End ≥3.5 idle characters Send Normal return Abnormal return * Frame Header ≥3.5 idle characters 1 Address 01 Address 01 Address 01 2 Function Code 41 Function Code 41 Function Code C1 3 Register Address 70 Register Address Hi 70 Exceptional 04(assumpti on) Hi Code 4 Register Address 00 Register Address Lo 00 CRC Parity Lo 70 Lo 5 Register Value Hi 00 Register Value Hi 00 CRC Parity Hi 53 6 Register Value Lo 07 Register Value Lo 07