sinee — 12.5 Example

EM500 Open-Loop Vector Control Inverter User Manual 3) Change carrier frequency (F00.23) to 4.0 kHz. (Since such function codes are expected to be saved in EEPROM usually after change, the function code 0x06 is used hereby). Send: 01 06 00 17 00 28 39 D0 Return: 01 06 00 17 00 28 39 D0 (Normal) Return:

01 86 04 43 A3 (When abnormal, assuming that slave fails) 410 Lo 5 Data Hi AA Data Hi AA CRC Parity Hi C3 6 Data Lo 55 Data Lo 55 5E 94 7 CRC Parity Lo 5E CRC Parity Lo 8 CRC Parity Hi 94 CRC Parity Hi * Frame End ≥3.5 idle characters Send Normal return Abnormal return * Frame Header ≥3.5 idle characters 1 Address 01 Address 01 Address 01 2 Function Code 06 Function Code 06 Function Code 86 3 Register Address Hi 00 Register Address Hi 00 Exceptional 04(assumpti C o d e 4 Register Address 17 Register Address Lo 17 CRC Parity Lo 43 Lo 5 Register Value Hi 00 Register Value Hi 00 CRC Parity Hi A3 6 Register Value Lo 28 Register Value Lo 28 7 CRC Parity Lo 39 CRC Parity Lo 39 8 CRC Parity Hi D0 CRC Parity Hi D0 * Frame End ≥3.5 idle characters