EM500 Open-Loop Vector Control Inverter User Manual 13.3.2.3 Write register or command function code, (0x600 , save EEPROM) The function code is used to write the non-holding register. The request message is the address and value to be written to the register. The normal status response message is the slave address + exception code. The function code can write up to two registers at a time. request message Response message Error message The following is an example of changing the device maximum frequency (F00.16) at address 1 to 50.00Hz:
418 CAN-ID 0x600+slave address DLC(Date Length) 4*N Data Field N*4 Bytes CAN-ID 0x600+ Host address DLC(Date Length) 2 Data Field Slave address+ Abnormal code(00) CAN-ID 0x680+ Host address DLC(Date Length) 1 Data Field Slave address+ Abnormal code request Response Domain Domain Domain (hexadecimal (hexadecimal) Name Name (hexadecimal) Name ) (normal) (Abnormal) CAN-ID 601 CAN-ID 67F CAN-ID 6FF Date 04 Date 02 Date 02 Length Length Length Register 00 Slave 01 Slave address 01 address address Hi