sinee — 6.2 Function Parameter Table

EM500 Open-Loop Vector Control Inverter User Manual 94 Uq=K*t=F/Fe*2*Split voltage source voltage) F05.01 Multipoint VF Frequency Point F1 0.00 - F05.03 Hz 0.50 ● F05.02 Multipoint VF Voltage Point V1 0.0 - 100.0 (100.0= Motor Rated Voltage) % 1.0 ● F05.03 Multipoint VF Frequency Point F2 F05.01 - F05.05 Hz 2.00 ● F05.04 Multipoint VF Voltage Point V2 0.0 - 100.0 % 4.0 ● F05.05 Multipoint VF Frequency Point F3 F05.03 - Motor Rated Frequency (Reference Frequency) Hz 5.00 ● F05.06 Multipoint VF Voltage Point V3 0.0 - 100.0 % 10.0 ● F05.07 Voltage Source of VF Separation Mode 0: Numeric Setting of VF Separation Voltage 1: AI1 2: AI2 3: AI3 4: High-Frequency Pulse (X7) 5: PID 6:

Communication Percentage Setting Note: Motor Rated Voltage is 100% 0 〇 F05.08 Numeric Setting of VF Separation Voltage 0.0 - 100.0 (100.0= Motor Rated Voltage) % 0.0 ● F05.09 Rise Time of VF Separation Voltage 0.00 - 60.00 s 2.00 ● F05.10 V/F Stator Voltage Drop Compensation Gain 0.00 - 200.00 % 100.00 ● F05.11 V/F Slip Compensation Gain 0.00 - 200.00 % 100.00 ● F05.12 V/F Slip Filter Time 0.00 - 10.00 s 1.00 ● F05.13 Oscillation Suppression Gain 0 - 20000 100 ● F05.14 Oscillation Suppression End Frequency 0.00 - 600.00 Hz 55.00 ●