EM600 High-Performance Vector Control Inverter User Manual 104 Function Name of Function Parameter Description Unit Default Property Code Code (Ud=0, Uq=K*t=Split voltage source voltage) 6:
VF Half-Split Mode (Ud=0, Uq=K*t=F/Fe*2*Split voltage source voltage) F14.81 Motor 2 Multipoint VF Frequency Point F1 0.00~F14.83 Hz 0.50 ● F14.82 Motor 2 Multipoint VF Voltage Point F1 0.0~100.0(100.0 = rated voltage) % 1.0 ● F14.83 Motor 2 Multipoint VF Frequency Point F2 F14.81~F14.85 Hz 2.00 ● F14.84 Motor 2 Multipoint VF Voltage Point F2 0.0~100.0 % 4.0 ● F14.85 Motor 2 Multipoint VF Frequency Point F3 F14.83~motor rated frequency (reference frequency) Hz 5.00 ● F14.86 Motor 2 Multipoint VF Voltage Point F3 0.0~100.0 % 10.0 ● F14.87 Stop Mode 0: Ramp-To-Stop 1:
Coast-to-Stop 0 〇 F15 Auxiliary Function Group F15.00 JOG Frequency 0.00 - Maximum Frequency F00.16 Hz 5.00 ● F15.01 JOG Acceleration Time 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 5.00 ● F15.02 JOG Deceleration Time 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 5.00 ● F15.03 Acceleration Time 2 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.04 Deceleration Time 2 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.05 Acceleration Time 3 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.06 Deceleration Time 3 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 - 65000 (F15.13=2) s 15.00 ● F15.07 Acceleration Time 4 0.00 - 650.00 (F15.13=0) s 15.00 ●