sinee — 6.2 Function Parameter Table

EM600 High-Performance Vector Control Inverter User Manual 107 Function Name of Function Parameter Description Unit Default Property Code Code 1: Enabled F15.40 Deceleration Time at Rapid Stop 0.00 - 650.00 (F15.13=0) 0.0 - 6500.0 (F15.13=1) 0 – 65000 (F15.13=2) s 1.00 ● F15.41 – F15.43 Not Used - - - - F16 Customized Function Group F16.00 Not Used F16.01 Set Length 1-65535 (F16.13=0) 0.

1-6553.5 (F16.13=1) 0.01-655.35 (F16.13=2) 0.001-65.535 (F16.13=3) m 1000 ● F16.02 Pulse Count Per Meter 0.1 - 6553.5 100.0 ● F16.03 Set Count Value F16.04 - 65535 1000 ● F16.04 Designated Count Value 1 - F16.03 1000 ● F16.05 Set Timed Run Time 0.0 - 6500.0 Disabled at 0.0 min 0.0 ● F16.06 Agent Password 0 - 65535 0 〇 F16.07 Set Accumulated Power-On Time Reach 0 - 65535, 0: Power-on Reach Time Protection Disabled H 0 〇 F16.08 Set Accumulated Run Time Reach 0 - 65535, 0:

Run Time Reach Protection Disabled H 0 〇 F16.09 Factory Password 0 - 65535 XXXXX ● F16.10 Analog Output percentage Correspongding to Zero of Setting Length/ Setting Count 0.00~100.00 % 0.00 〇 F16.11 Analog Output Percentage Correspongding to Setting Value of Setting Iength/ Setting Count 0.00~100.00 % 100.00 〇