sinee — 6.2 Function Parameter Table

EM600 High-Performance Vector Control Inverter User Manual 106 Function Name of Function Parameter Description Unit Default Property Code Code FDT2 F15.24 FDT2 Hysteresis -(Fmax-F15.23)~F15.23 Hz 2.00 〇 F15.25 Analog Quantity Level Detection ADT 0: AI1 1: AI2 2: AI3 3: AI4 (Expansion Card) 0 ○ F15.26 Analog Quantity Level Detection ADT1 0.00 - 100.00 % 20.00 ● F15.27 ADT1 Hysteresis 0.00 - F15.26 (Monotonic decreasing is active) % 5.00 ● F15.28 Analog Quantity Level Detection ADT2 0.00 - 100.00 % 50.00 ● F15.29 ADT2 Hysteresis 0.00 - F15.28 (Monotonic decreasing is active) % 5.00 ● F15.30 Energy Consumption Brake 0: Disabled 1:

Enabled 0 〇 F15.31 Operation Voltage of Dynamic Brake 110.0 - 140.0 (380V, 100.0=537V) % 128.5 ● F15.32 Brake Duty Ratio 20 - 100 (100 means that duty ratio is 1) % 100 ● F15.33 Control Mode of Set Frequency Lower Than Lower Limit Frequency 0: Run at Lower Limit Frequency 1: Stop 2: Run at Zero Speed 0 〇 F15.34 Fan Control 0: Run at Energization 1: Run at Start 2: Run at Intelligent Temperature Control 1 〇 F15.35 Overmodulation Intensity 1.00 - 1.10 1.05 ● F15.36 PWM Modulation Method Switching Options 0: Disabled (7 preset PWM modulation) 1: